5-210
IM DLM4038-17EN
:SERialbus<x>:SENT[:ANALyze]:SETup:S
TYPe
Function Sets or queries the SENT signal analysis slow
channel format.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:S
TYPe {ENHanced|SHORt}
:SERialbus<x>:SENT[:ANALyze]:SETup:S
TYPe?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:STY
PE ENHANCED
:SERIALBUS1:SENT:ANALYZE:SETUP:STY
PE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:ST
YPE ENHANCED
:SERialbus<x>:SENT[:ANALyze]:SETup:S
OURce
Function Sets or queries the SENT signal analysis source.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:S
OURce {<NRf>|MATH<y>|PODA<y>|PODB<y>
|PODL<y>}
:SERialbus<x>:SENT[:ANALyze]:SETup:S
OURce?
<x> = 1 to 4
<NRf> = 1 to 8
<y> of MATH<y> = 1 to 4
<y> of PODA<y>, PODB<y>, PODL<y> = 0 to 7
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:SOUR
CE 1
:SERIALBUS1:SENT:ANALYZE:SETUP:SOUR
CE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:SO
URCE 1
:SERialbus<x>:SENT:DETail?
Function Queries all SENT signal analysis list settings.
Syntax
:SERialbus<x>:SENT:DETail?
<x> = 1 to 4
:SERialbus<x>:SENT:DETail:DISPlay
Function Sets or queries the display mode for the SENT
signal analysis list.
Syntax
:SERialbus<x>:SENT:DETail:DISPlay {F
ULL|LOWer|UPPer}
:SERialbus<x>:SENT:DETail:DISPlay?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:DETAIL:DISPLAY FULL
:SERIALBUS1:SENT:DETAIL:DISPLAY?
-> :SERIALBUS1:SENT:DETAIL:DISPLAY F
ULL
:SERialbus<x>:SENT:DETail:LIST:ALL?
Function Queries all the data for all analysis numbers in
the SENT signal analysis result list.
Syntax
:SERialbus<x>:SENT:DETail:LIST:ALL?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:DETAIL:LIST:ALL?
-> #8
(number of bytes, 8 digits)(data sequence)
Description All the data for all analysis numbers are returned
in <block data> format.
The data of each analysis number is separated
by ASCII code 0AH.
:SERialbus<x>:SENT:DETail:LIST:ITEM?
Function Queries all items that will be displayed in the
SENT signal analysis result list.
Syntax
:SERialbus<x>:SENT:DETail:LIST:ITEM?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:DETail:LIST:ITEM?
-> :SERIALBUS1:SENT:DETAIL:LIST:
ITEM "No.,Time(ms),Sync(us),Tick(us)
,S&C,Data,CRC,Length(tick),Informati
on,SlowCH,"
Description
The items displayed in the analysis
result list varies depending on the
:SERialbus<x>:SENT[:ANALyze]:SETup:D
ISPlay {BOTH|FAST|SLOW} setting.
:SERialbus<x>:SENT:DETail:LIST:VAL
ue?
Function Queries all the data for the specified analysis
number in the SENT signal analysis result list.
Syntax
:SERialbus<x>:SENT:DETail:LIST:VAL
ue? {<NRf>|MAXimum|MINimum}
<x> = 1 to 4
<NRf> = –100000 to 100000
Example :SERIALBUS1:SENT:DETail:LIST:VAL
UE? 0
-> :SERIALBUS1:SENT:DETAIL:LIST:VAL
UE "0,-0.1672,168.00,3.00,1100,6,3,
5,E,B,9,3,283.73,,,"
Description The items displayed in the analysis result
list varies depending on the
:SERialbus
<x>:SENT[:ANALyze]:SETup:DISPl
ay {BOTH|FAST|SLOW}
setting.
5.25 SERialbus Group