Index
:SERialbus<x>:SENT:SEARch?
Function Queries all SENT signal search settings.
Syntax
:SERialbus<x>:SENT:SEARch?
<x> = 1 to 4
:SERialbus<x>:SENT:SEARch:ABORt
Function Aborts the SENT signal search.
Syntax
:SERialbus<x>:SENT:SEARch:ABORt
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:ABORT
:SERialbus<x>:SENT:SEARch:EXECute
Function Executes a SENT signal search.
Syntax
:SERialbus<x>:SENT:SEARch:EXECute
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:EXECUTE
:SERialbus<x>:SENT:SEARch:SELect
Function Queries which detected point to display in the
SENT signal search zoom window and queries
the zoom position of the detected point.
Syntax
:SERialbus<x>:SENT:SEARch:SELe
ct {<NRf>|MAXimum}
:SERialbus<x>:SENT:SEARch:SELect?
<x> = 1 to 4
<NRf> = 0 to 49999
Example
:SERIALBUS1:SENT:SEARCH:SELECT 1
:SERIALBUS1:SENT:SEARCH:SELECT?
-> :SERIALBUS1:SENT:SEARCH:
SELECT 1.50000000
Description If there are no detected points, the DLM4000
returns “NAN.”
:SERialbus<x>:SENT:SEARch:SELe
ct? MAXimum
Function Queries the number of detected points in the
SENT signal search.
Syntax
:SERialbus<x>:SENT:SEARch:SELe
ct? {MAXimum}
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SELECT? MAXi
mum
-> :SERIALBUS1:SENT:SEARCH:
SELECT 100
Description If there are no detected points, the DLM4000
returns “NAN.”
:SERialbus<x>:SENT:SEARch:SETup?
Function Queries all SENT signal search condition
settings.
Syntax
:SERialbus<x>:SENT:SEARch:SETup?
<x> = 1 to 4
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror?
Function Queries all SENT signal search error settings.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror?
<x> = 1 to 4
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:FCRC
Function Sets or queries the SENT signal search fast
channel CRC error.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:FCRC {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:FCRC?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
FCRC ON
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
FCRC?
-> :SERIALBUS1:SENT:SEARCH:SETUP:ERR
OR:FCRC 1
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:NDValue
Function Sets or queries the SENT signal search nibble
data value error.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:NDValue {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:NDValue?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
NDVALUE ON
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
NDVALUE?
-> :SERIALBUS1:SENT:SEARCH:SETUP:ERR
OR:NDVALUE 1
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:NNUMber
Function Sets or queries the SENT signal search nibble
data count error.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:NNUMber {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:NNUMber?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
NNUMBER ON
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
NNUMBER?
-> :SERIALBUS1:SENT:SEARCH:SETUP:ERR
OR:NNUMBER 1