Page #245 background imageLoading...
Page #245 background image
5-212
IM DLM4038-17EN
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SAComm
Function Sets or queries the SENT signal search status
and communication error.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SAComm {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SAComm?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
SACOMM ON
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
SACOMM?
-> :SERIALBUS1:SENT:SEARCH:SETUP:ERR
OR:SACOMM 1
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SCRC
Function Sets or queries the SENT signal search slow
channel CRC error.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SCRC {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SCRC?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
SCRC ON
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
SCRC?
-> :SERIALBUS1:SENT:SEARCH:SETUP:ERR
OR:SCRC 1
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SCPulses
Function Sets or queries the SENT signal search
consecutive calibration pulse error.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SCPulses{<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:ER
Ror:SCPulses?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
SCPULSESON
:SERIALBUS1:SENT:SEARCH:SETUP:ERROR:
SCPULSES?
-> :SERIALBUS1:SENT:SEARCH:SETUP:ERR
OR:SCPULSES 1
Description When
:SERialbus<x>:SENT[:ANALyze]:S
ETup:FORMat:CEFactor:SCPulses
is set to
OFF
, this setting is fixed to
OFF
.
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa?
Function Queries all fast channel data settings for SENT
signal searching.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa?
<x> = 1 to 4
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>?
Function Queries all settings related to the specified user
data of the SENT signal search fast channel.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>:CONDition
Function Sets or queries the comparison condition of the
specified user data of the SENT signal search
fast channel.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>:CONDition {BETWeen|EQUal
|GREater|LESS|NOTBetween|NOTEqul}
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>:CONDition?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:FDATA:
DATA1:CONDITION BETWEEN
:SERIALBUS1:SENT:SEARCH:SETUP:FDATA:
DATA1:CONDITION?
-> :SERIALBUS1:SENT:SEARCH:SETUP:FDA
TA:DATA1:CONDITION BETWEEN
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>:DECimal<z>
Function Sets or queries the data of the specified user
data of the SENT signal search fast channel in
decimal notation.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>:DECimal<z> {<NRf>}
:SERialbus<x>:SENT:SEARch[:SETup]:FD
ATa:DATA<y>:DECimal<z>?
<x> = 1 to 4
<y> = 1 to 4
<z> = 1 or 2
<NRf> = See the DLM4000 Features Guide for
this information.
Example
:SERIALBUS1:SENT:SEARCH:SETUP:FDATA:
DATA1:DECIMAL1 1
:SERIALBUS1:SENT:SEARCH:SETUP:FDATA:
DATA1:DECIMAL1?
-> :SERIALBUS1:SENT:SEARCH:SETUP:FDA
TA:DATA1:DECIMAL1 1
5.25 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals