IM DLM4038-17EN
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:HEXa
Function Sets the ID value, which is one of the ID OR
conditions, for CAN FD bus signal triggering in
hexadecimal notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:HEXa {<Strin
g>}
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:ID1:HEXA "1AB"
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the ID OR conditions, for CAN FD
bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:MODE {<Boole
an>}
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:MODE?
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:ID1:MODE ON
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:ID1:MODE?
-> :TRIGGER:ATRIGGER:CANFD:IDOR:IDEN
TIFIER:ID1:MODE 1
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:PATTern
Function Sets or queries the ID condition, which is one
of the ID OR conditions, for CAN FD bus signal
triggering in binary notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:PATTern {<St
ring>}
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:ID<x>:PATTern?
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:ID1:PATTERN "11100001111"
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:ID1:PATTERN?
-> :TRIGGER:ATRIGGER:CANFD:IDOR:IDEN
TIFIER:ID1:PATTERN "11100001111"
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:MFORmat
Function Sets or queries the ID frame format (standard or
extended), which is one of the ID OR conditions,
for CAN FD bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:MFORmat {EXTended|
STANdard}
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:MFORmat?
Example
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:MFORMAT EXTENDED
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:MFORMAT?
-> :TRIGGER:ATRIGGER:CANFD:IDOR:IDEN
TIFIER:MFORMAT EXTENDED
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the ID OR conditions, for CAN FD
bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:MODE {<Boolean>}
Example
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:MODE ON
-> :TRIGGER:ATRIGGER:CANFD:IDOR:IDEN
TIFIER:MODE 1
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:PFORmat
Function Sets or queries the ID input format, which is one
of the ID OR conditions, for CAN FD bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:PFORmat {BINary|HE
Xa|MESSage}
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:IDENtifier:PFORmat?
Example
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:PFORMAT BINARY
:TRIGGER:ATRIGGER:CANFD:IDOR:IDENTIF
IER:PFORMAT?
-> :TRIGGER:ATRIGGER:CANFD:IDOR:IDEN
TIFIER:PFORMAT BINARY
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:MSIGnal<x>:MESSage:ITEM
Function Sets the message item, which is one of the ID
OR conditions, for CAN FD bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:CANF
D:IDOR:MSIGnal<x>:MESSage:ITEM {<Str
ing>}
<x> = 1 to 4
<String> = Up to 32 characters
Example
:TRIGGER:ATRIGGER:CAN:IDOR:MSIGNAL1:
MESSAGE:ITEM "TEST"
5.34 TRIGger Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals