Loading...
5-278
IM DLM4038-17EN
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the ID and data conditions, for
LIN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:MODE ON
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:MODE?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDEN
TIFIER:ID:MODE 1
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:PATTern
Function Sets or queries the ID value for LIN bus signal
triggering in binary notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:PATTern {<Strin
g>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:PATTern?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:PATTERN "101100"
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:PATTERN?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDEN
TIFIER:ID:PATTERN "101100"
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:PFORmat
Function Sets or queries the ID input format, which is one
of the ID and data conditions, for LIN bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:PFORmat {BINary|HE
Xa}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:PFORmat?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:PFORMAT BINARY
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:PFORMAT?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDEN
TIFIER:PFORMAT BINARY
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR?
Function Queries all IDOR condition settings for LIN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier?
Function Queries all IDOR condition ID settings for LIN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>?
Function Queries an ID value, which is one of the IDOR
condition settings, for LIN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>?
<x> = 1 to 4
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:HEXa
Function Sets the ID value, which is one of the IDOR
conditions, for LIN bus signal triggering in
hexadecimal notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:HEXa {<String>}
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:LIN:IDOR:IDENTIFIE
R:ID1:HEXA "1E"
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the IDOR conditions, for LIN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:
MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:MODE?
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:LIN:IDOR:IDENTIFIE
R:ID1:MODE ON
:TRIGGER:ATRIGGER:LIN:IDOR:IDENTIFIE
R:ID1:MODE?
-> :TRIGGER:ATRIGGER:LIN:IDOR:IDENTI
FIER:ID1:MODE 1
5.34 TRIGger Group

Table of Contents

Other manuals for YOKOGAWA DLM4038