EasyManuals Logo

YOKOGAWA DLM4038 User Manual

YOKOGAWA DLM4038
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #311 background imageLoading...
Page #311 background image
5-278
IM DLM4038-17EN
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the ID and data conditions, for
LIN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:MODE?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:MODE ON
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:MODE?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDEN
TIFIER:ID:MODE 1
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:PATTern
Function Sets or queries the ID value for LIN bus signal
triggering in binary notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:PATTern {<Strin
g>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:ID:PATTern?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:PATTERN "101100"
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:ID:PATTERN?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDEN
TIFIER:ID:PATTERN "101100"
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:PFORmat
Function Sets or queries the ID input format, which is one
of the ID and data conditions, for LIN bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:PFORmat {BINary|HE
Xa}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDData:IDENtifier:PFORmat?
Example
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:PFORMAT BINARY
:TRIGGER:ATRIGGER:LIN:IDDATA:IDENTIF
IER:PFORMAT?
-> :TRIGGER:ATRIGGER:LIN:IDDATA:IDEN
TIFIER:PFORMAT BINARY
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR?
Function Queries all IDOR condition settings for LIN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier?
Function Queries all IDOR condition ID settings for LIN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>?
Function Queries an ID value, which is one of the IDOR
condition settings, for LIN bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>?
<x> = 1 to 4
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:HEXa
Function Sets the ID value, which is one of the IDOR
conditions, for LIN bus signal triggering in
hexadecimal notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:HEXa {<String>}
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:LIN:IDOR:IDENTIFIE
R:ID1:HEXA "1E"
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:MODE
Function Sets or queries the ID enable/disable condition,
which is one of the IDOR conditions, for LIN bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:
MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
IDOR:IDENtifier:ID<x>:MODE?
<x> = 1 to 4
Example
:TRIGGER:ATRIGGER:LIN:IDOR:IDENTIFIE
R:ID1:MODE ON
:TRIGGER:ATRIGGER:LIN:IDOR:IDENTIFIE
R:ID1:MODE?
-> :TRIGGER:ATRIGGER:LIN:IDOR:IDENTI
FIER:ID1:MODE 1
5.34 TRIGger Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals