:ANALysis:PANalyze<x>:HARMonics?
Function Queries all harmonic analysis settings.
Syntax
:ANALysis:PANalyze<x>:HARMonics?
<x> = 1 to 2
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss?
Function Queries all class C harmonic analysis settings.
Syntax
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss?
<x> = 1 to 2
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:GETLambda
Function Queries the current power factor for class C
harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:GETLambda
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:CCLASS
:GETLAMBDA
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:LAMBda
Function Sets or queries the power factor for class C
harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:LAMBda {<NRf>}
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:LAMBda?
<x> = 1 to 2
<NRf> = 0.001 to 1
Example
:ANALYSIS:PANALYZE1:HARMONICS:
CCLASS:LAMBDA 0.10
:ANALYSIS:PANALYZE1:HARMONICS:
CCLASS:LAMBDA?
-> :ANALYSIS:PANALYZE1:HARMONICS:CCL
ASS:LAMBDA100.0E−03
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:MAXCurrent
Function Sets or queries the fundamental current value for
class C harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:MAXCurrent {<NRf>|<Current>}
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:MAXCurrent?
<x> = 1 to 2
<NRf>, <Current> = 0.001 to 100 (A)
Example
:ANALYSIS:PANALYZE1:HARMONICS:
CCLASS:MAXCURRENT 50A
:ANALYSIS:PANALYZE1:HARMONICS:
CCLASS:MAXCURRENT?
-> :ANALYSIS:PANALYZE1:HARMONICS:CCL
ASS:MAXCURRENT 50.000E+00
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:OPOWer
Function Sets or queries whether or not the active power
for class C harmonic analysis exceeds 25 W.
Syntax
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:OPOWer {FALSe|TRUE}
:ANALysis:PANalyze<x>:HARMonics:CCLa
ss:OPOWer?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:
CCLASS:OPOWER FALSE
:ANALYSIS:PANALYZE1:HARMONICS:
CCLASS:OPOWER?
-> :ANALYSIS:PANALYZE1:HARMONICS:CCL
ASS:OPOWER FALSE
:ANALysis:PANalyze<x>:HARMonics:CLA
Ss
Function Sets or queries the class of the device under
harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:CLA
Ss {A|B|C|D}
:ANALysis:PANalyze<x>:HARMonics:CLA
Ss?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:CLA
SS A
:ANALYSIS:PANALYZE1:HARMONICS:CLASS?
-> :ANALYSIS:PANALYZE1:HARMONICS:CLA
SS A
:ANALysis:PANalyze<x>:HARMonics:DCLa
ss?
Function Queries all class D harmonic analysis settings.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DCLa
ss?
<x> = 1 to 2
:ANALysis:PANalyze<x>:HARMonics:DCLa
ss:POWer
Function Sets or queries the power value for class D
harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DCLa
ss:POWer {<NRf>}
:ANALysis:PANalyze<x>:HARMonics:DCLa
ss:POWer?
<x> = 1 to 2
<NRf> = −1.0000E+31 to 1.0000E+31
Example
:ANALYSIS:PANALYZE1:HARMONICS:
DCLASS:POWER 1V
:ANALYSIS:PANALYZE1:HARMONICS:
DCLASS:POWER?
-> :ANALYSIS:PANALYZE1:HARMONICS:DCL
ASS:POWER 1.000E+00
5.3 ANALysis Group