Page #98 background imageLoading...
Page #98 background image
5-65
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:ANALysis:PANalyze<x>:HARMonics:DETa
il?
Function Queries all harmonic analysis result list settings.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DETa
il?
<x> = 1 to 2
:ANALysis:PANalyze<x>:HARMonics:DETa
il:DISPlay
Function Sets or queries the display position of the
analysis result list of harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DETa
il:DISPlay {FULL|LOWer|UPPer}
:ANALysis:PANalyze<x>:HARMonics:DETa
il:DISPlay?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:
DETAIL:DISPLAY FULL
:ANALYSIS:PANALYZE1:HARMONICS:
DETAIL:DISPLAY?
-> :ANALYSIS:PANALYZE1:HARMONICS:DET
AIL:DISPLAY FULL
:ANALysis:PANalyze<x>:HARMonics:DETa
il:LIST:ITEM?
Function Queries the items displayed in the harmonic
analysis result list.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DETa
il:LIST:ITEM?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:
DETAIL:LIST:ITEM?
-> :ANALYSIS:PANALYZE1:HARMONICS:DET
AIL:LIST:ITEM "Order.,Measure (A),
Limit (A),Measure (%),Limit (%),
Info,"
:ANALysis:PANalyze<x>:HARMonics:DETa
il:LIST:VALue?
Function Queries all of the data for the specified analysis
number in the harmonic analysis result list.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DETa
il:LIST:VALue? {<NRf>}
<x> = 1 to 2
<NRf> = 2 to 40 (harmonic order)
Example
:ANALYSIS:PANALYZE1:HARMONICS:
DETAIL:LIST:VALUE? 2
-> :ANALYSIS:PANALYZE1:HARMONICS:
DETAIL:LIST:VALUE " 2, 0.031,
0.020, 3.149, 2.000,NG,"
:ANALysis:PANalyze<x>:HARMonics:DMO
De
Function Sets or queries the harmonic analysis display
mode.
Syntax
:ANALysis:PANalyze<x>:HARMonics:DMO
De {LINear|LOG}
:ANALysis:PANalyze<x>:HARMonics:DMO
De?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:DMO
DE LINEAR
:ANALYSIS:PANALYZE1:HARMONICS:DMODE?
-> :ANALYSIS:PANALYZE1:HARMONICS:DMO
DE LINEAR
:ANALysis:PANalyze<x>:HARMonics:GROu
ping
Function Sets or queries the harmonic analysis grouping.
Syntax
:ANALysis:PANalyze<x>:HARMonics:GROu
ping {OFF|TYPE1|TYPE2}
:ANALysis:PANalyze<x>:HARMonics:GROu
ping?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:HARMONICS:GROUPI
NG OFF
:ANALYSIS:PANALYZE1:HARMONICS:GROUPI
NG?
-> :ANALYSIS:PANALYZE1:HARMONICS:GRO
UPING OFF
:ANALysis:PANalyze<x>:HARMonics:SPOi
nt
Function Sets or queries the harmonic analysis
computation start point.
Syntax
:ANALysis:PANalyze<x>:HARMonics:SPOi
nt {<NRf>}
:ANALysis:PANalyze<x>:HARMonics:SPOi
nt?
<x> = 1 to 2
<NRf> = −5 to 5 (divisions)
Example
:ANALYSIS:PANALYZE1:HARMONICS:SPOI
NT 1
:ANALYSIS:PANALYZE1:HARMONICS:SPOI
NT?
-> :ANALYSIS:PANALYZE1:HARMONICS:SPO
INT 1.000E+00
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals