5-66
IM DLM4038-17EN
:ANALysis:PANalyze<x>:HARMonics:SVOL
tage
Function Sets or queries the power supply voltage for
harmonic analysis.
Syntax
:ANALysis:PANalyze<x>:HARMonics:SVOL
tage {<NRf>|<Voltage>}
:ANALysis:PANalyze<x>:HARMonics:SVOL
tage?
<x> = 1 to 2
<NRf>, <Voltage> = 90 to 440 V
Example
:ANALYSIS:PANALYZE1:HARMONICS:SVOLTA
GE 230
:ANALYSIS:PANALYZE1:HARMONICS:SVOLTA
GE?
-> :ANALYSIS:PANALYZE1:HARMONICS:SVO
LTAGE 230.00000E+00
:ANALysis:PANalyze<x>:I2T?
Function Queries all Joule integral settings.
Syntax
:ANALysis:PANalyze<x>:I2T?
<x> = 1 to 2
:ANALysis:PANalyze<x>:I2T:MATH
Function Sets or queries the on/off status of the Joule
integral waveform display.
Syntax
:ANALysis:PANalyze<x>:I2T:MATH {I2T|
OFF}
:ANALysis:PANalyze<x>:I2T:MATH?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:I2T:MATH I2T
:ANALYSIS:PANALYZE1:I2T:MATH?
-> :ANALYSIS:PANALYZE1:I2T:MATH I2T
:ANALysis:PANalyze<x>:I2T:MEASure?
Function Queries all Joule integral automatic measurement
settings.
Syntax
:ANALysis:PANalyze<x>:I2T:MEASure?
<x> = 1 to 2
:ANALysis:PANalyze<x>:I2T:MEASure:I
2T?
Function Queries Joule integral settings.
Syntax
:ANALysis:PANalyze<x>:I2T:MEASure:I
2T?
<x> = 1 to 2
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:COUNt?
Function Queries the normal statistical processing count of
the Joule integral.
Syntax
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:COUNt?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:I2T:MEASURE:I2T:
COUNT?
-> :ANALYSIS:PANALYZE1:I2T:MEASURE:I
2T:COUNT 100
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:{MAXimum|MEAN|MINimum|SDEViation}?
Function Queries a statistical value of a Joule integral.
Syntax
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:MAXimum?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:I2T:MEASURE:I2T:
MAXIMUM?
-> :ANALYSIS:PANALYZE1:I2T:MEASURE:I
2T:MAXIMUM 10.0000E+03
Description If the statistical value is immeasurable, the
DLM4000 returns “NAN” (not a number).
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:STATe
Function Sets or queries whether or not a Joule integral
will be measured.
Syntax
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:STATe {<Boolean>}
:ANALysis:PANalyze<x>:I2T:MEASure:I2
T:STATe?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:I2T:MEASURE:I2T:
STATE ON
:ANALYSIS:PANALYZE1:I2T:MEASURE:I2T:
STATE?
-> :ANALYSIS:PANALYZE1:I2T:MEASURE:I
2T:STATE 1
5.3 ANALysis Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals