B2-18
IM 34M06H62-02E 2nd Edition : June 2008-00
Table B2.24 PID Parameters (1/4)
Data Position Numbe
r
Symbol Description Unit Data Range Default Value Attribute Stored
See
Also
Loop 1 Loop 2 Loop 3 Loop 4
201 401 601 801 1.SP Set point Industrial
PRL to PRH PRL RW Irregular
B2.4
C4.1
202 402 602 802 1.A1
A
larm 1 preset value
Industrial
-30000 to 30000
PRH RW
C8
203 403 603 803 1.A2
A
larm 2 preset value
PRL RW
204 404 604 804 1.A3
A
larm 3 preset value
PRH RW
205 405 605 805 1.A4
A
larm 4 preset value
PRL RW
206 406 606 806 1.PB
Proportional band
%
1
to 9999
(0.1
to 999.9%)
50 RW
C6.2
207 407 607 807 1.TI
Integral time Second
0:
OFF,
1
to 6000
(1
to 6000
s)
240 RW
C6.3
208 408 608 808 1.TD
Derivative time Second
0:
OFF,
1
to 6000
(1
to 6000
s)
60 RW
C6.4
209 409 609 809 1.OH
Upper output limit
%
-5.0 to 105.0% if OL < OH
Fixed at OL if OL OH
1000 RW
C2.4.2
210 410 610 810 1.OL Lower output limit
0
(1000 in heating/
cooling control)
RW
211 411 611 811 1.MR Manual reset value
%
-5.0
to 105.0%
500 RW
C6.3
212 412 612 812 1.HYS
ON/OFF control
hysteresis
Industrial
0 to (PRH - PRL) (PRH - PRL) x 0.5% RW C2.4.1
213 413 613 813 1.DR
Forward/
reverse switch
None
0: Reverse
1: Forward
(always 0 in heating/cooling
control)
0 RW
C6.1
214 414 614 814 1.GAIN.C Cooling gain %
1
to 999
(1 to 999%)
100 RW
C2.4.3
215 415 615 815 1.HYS.C
Cooling ON/OFF control
hysteresis
Industrial
0 to (PRH - PRL) (PRH - PRL) x 0.5% RW C2.4.4
216 416 616 816 1.DB Dead band Industrial
PID control:
-10.0 to 10.0% of (PRH - PRL)
ON/OFF control:
-50.0 to 50.0% of (PRH - PRL)
0 RW
C2.4.3
C2.4.4
217 417 617 817 1.POUT Preset output %
-50
to 1050
(-5.0
to 105.0%)
0 RW
C7.1
218 418 618 818 1.POUT.C Cooling preset output
%
-50
to 1050
(-5.0
to 105.0%)
0 RW
Irregular: You need to execute a specific procedure every time to update stored set point values.
Table B2.24 PID Parameters (2/4)
Data Position Numbe
r
Symbol Description Unit Data Range Default Value Attribute Stored
See
Also
Loop 1 Loop 2 Loop 3 Loop 4
221 421 621 821 2.SP Set point Industrial
PRL to PRH PRL RW Irregular
B2.4
C4.1
222 422 622 822 2.A1
A
larm 1 preset value
Industrial
-30000 to 30000
PRH RW
C8
223 423 623 823 2.A2
A
larm 2 preset value
PRL RW
224 424 624 824 2.A3
A
larm 3 preset value
PRH RW
225 425 625 825 2.A4
A
larm 4 preset value
PRL RW
226 426 626 826 2.PB
Proportional band
%
1 to 9999 (0.1 to 999.9%)
50 RW
C6.2
227 427 627 827 2.TI
Integral time Second
0: OFF, 1 to 6000 (1 to 6000 s)
240 RW
C6.3
228 428 628 828 2.TD
Derivative time second
0: OFF, 1 to 6000 (1 to 6000 s)
60 RW
C6.4
229 429 629 829 2.OH
Upper output limit
%
-5.0 to 105.0% if OL < OH
Fixed at OL if OL OH
1000 RW
C2.4.2
230 430 630 830 2.OL Lower output limit
0 (1000 in heating/
cooling control)
RW
231 431 631 831 2.MR Manual reset value
%
-5.0 to 105.0%
500 RW
C6.3
232 432 632 832 2.HYS
ON/OFF control
hysteresis
Industrial
0 to (PRH - PRL) (PRH - PRL) x 0.5% RW C2.4.1
233 433 633 833 2.DR
Forward/
reverse switch
None
0: Reverse
1: Forward
(Always 0 in heating/cooling
control)
0 RW
C6.1
234 434 634 834 2.GAIN.C Cooling gain %
1 to 999 (1 to 999%)
100 RW
C2.4.3
235 435 635 835 2.HYS.C
Cooling ON/OFF control
hysteresis
Industrial
0 to (PRH - PRL) (PRH - PRL) x 0.5% RW C2.4.4
236 436 636 836 2.DB Dead band Industrial
PID control:
-10.0 to 10.0% of (PRH - PRL)
ON/OFF control:
-50.0 to 50.0% of (PRH - PRL)
0 RW
C2.4.3
C2.4.4
237 437 637 837 2.POUT Preset output %
-50 to 1050 (-5.0 to 105.0%)
0 RW
C7.1
238 438 638 838 2.POUT.C Cooling preset output
%
-50 to 1050 (-5.0 to 105.0%)
0 RW
Irregular: You need to execute a specific procedure every time to update stored set point values.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA F3CU04-0S and is the answer not in the manual?

YOKOGAWA F3CU04-0S Specifications

General IconGeneral
BrandYOKOGAWA
ModelF3CU04-0S
CategoryControl Unit
LanguageEnglish

Related product manuals