EasyManua.ls Logo

Zodiac pH Link - Page 34

Zodiac pH Link
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
5.2.6 Programming the "HYDROX" chlorinaon mes
If a ltraon programme has been dened, the chlorinaon programme will be idencal to the ltraon programme(s)
by default. They can be changed, however the chlorinaon programmes cannot be acvated outside of the ltraon
programmes for safety reasons.
Press and browse using the buons. Conrm the selecon by pressing .
Select "HYDROX TIMER 1" or "HYDROX TIMER 2":
Set the chlorinaon mes "ON" and "OFF" using the buons.
Conrm the selecon by pressing .
The chlorinaon duraon must be less than or equal to the ltraon duraon
The appliance does not allow for a me delay for chlorinaon that exceeds or that falls outside of the
programmed ltraon duraon.
Press to exit.
When the chlorinaon mes programme has been conrmed, the leer "T" is shown on the screen:
When the chlorinaon and ltraon mes programmes have been conrmed, the leer "P" is shown on
the screen:
EN