44
5.3.4 Conguring the ORP setpoint
The ORP setpoint conguraon determines the me at which chlorine is produced by the appliance. The level of free
chlorine must be controlled at regular intervals aer inial installaon. The default value of the ORP setpoint is 700 mV.
The value of the setpoint depends on the pool's environment, its auence, and the amount of stabiliser present in the
pool water, etc.
• Press and browse the menu using the buons. Press to conrm.
• Select the desired setpoint value (from 600 mV to 900 mV) using the buons.
• Press to conrm.
(ORP = Oxidaon Reducon Potenal)
5.3.5 Acvang the pH pump
To prevent exposure to acid during installaon, the dispenser pump is deacvated for the rst 8 hours of operaon;
during these rst 8 hours, the pH value is measured and displayed as "- - - -".
• Hydrochloric acid is a hazardous chemical that may cause burns, lesions and irritaons.
Handle with care and use protecve equipment (gloves, safety glasses, overalls). Refer to the
product's MSDS for more informaon.
• Always pour the acid into the water.
• Once cleaning is complete, dispose of the soluon according to the standard in force in the
country of use.
• The pH pump can be manually acvated during this 8-hour period; press and browse the menu
using the
buons. Press to conrm.
• Press to exit.