Chapter 11 Management
IES4005M User’s Guide
85
alarm notification-severity <severity>
Configures the minimum severity level for
sending out alarm notifications (SNMP trap
and SYSLOG) about the specified ports.
C13
show interface voip <slot/portlist> alarm line-
control
Displays the time interval settings for
reporting alarms when you enable alarm line-
control on the specified DSL ports.
E1
show interface voip <slot/portlist> alarm
notification-severity
Displays the minimum severity level to send
out alarm notifications (SNMP trap and
SYSLOG) on the specified DSL ports.
E1
interface voip <slot/portlist>
Enters the sub-command mode for configuring
the specified VoIP ports.
C13
exit
Leaves the VoIP port configuration sub-
command mode.
C13
alarm notification-severity <severity>
Configures the minimum severity level for
sending out alarm notifications (SNMP trap
and SYSLOG).
C13
alarm line-control
Has the IES report alarms for the ports at
regular intervals instead of immediately.
C13
no alarm line-control
Turns off interval-based reporting of alarms so
the IES reports alarms immediately.
C13
alarm line-control interval <interval>
Sets the time interval (10-600 seconds) the
IES uses for sending alarms about these
ports. This applies when you enable alarm
line-control on these ports.
C13
show interface ge <port> alarm notification-
severity
Displays the minimum severity level to send
out alarm notifications (SNMP trap and
SYSLOG) on the specified Gigabit Ethernet
uplink interfaces.
You can specify a single port <1>, all ports
<*> or a list of ports <1,2>. You can also
include a range of ports <1-2>.
E1
show interface ge <port> alarm line-control
Displays the time interval settings for
reporting alarms when you enable alarm line-
control on the specified Gigabit Ethernet
uplink interfaces.
You can specify a single port <1>, all ports
<*> or a list of ports <1,2>. You can also
include a range of ports <1-2>.
E1
interface ge-nni <portlist>
Configures the specified Gigabit Ethernet
uplink ports. You can specify a single port
<1>, all ports <*> or a list of ports <1,2>.
You can also include a range of ports <1-2>.
C13
exit
Leaves the Gigabit Ethernet uplink port
configuration.
C13
alarm notification-severity <severity>
Configures the minimum severity level for
sending out alarm notifications (SNMP trap
and SYSLOG).
C13
alarm line-control
Has the IES report alarms for the ports at
regular intervals instead of immediately.
C13
no alarm line-control
Turns off interval-based reporting of alarms so
the IES reports alarms immediately.
C13
Table 58 Alarm Commands Summary (continued)
COMMAND DESCRIPTION M P