Chapter 9 Interfaces
NXC Series User’s Guide
153
Remove Select an entry and click this to delete it from this table.
Object
References
Select an entry and click Object References to open a screen that shows which settings use
the entry. See Section 9.2.2 on page 156 for an example.
# This field is a sequential value, and it is not associated with any entry.
Name This field displays the name of the DHCPv6 request object.
Type This field displays the type of the object.
Value This field displays the IPv6 address that the NXC obtained from an uplink router.
Interface Parameters
Egress Bandwidth Enter the maximum amount of traffic, in kilobits per second, the NXC can send through the
interface to the network. Allowed values are 0 - 1048576.
Ingress
Bandwidth
This is reserved for future use.
Enter the maximum amount of traffic, in kilobits per second, the NXC can receive from the
network through the interface. Allowed values are 0 - 1048576.
MTU Maximum Transmission Unit. Type the maximum size of each data packet, in bytes, that can
move through this interface. If a larger packet arrives, the NXC divides it into smaller
fragments. Allowed values are 1280 - 1500. Usually, this value is 1500.
Connectivity Check These fields appear when you set the Interface Type to External or General.
The interface can regularly check the connection to the gateway you specified to make
sure it is still available. You specify how often the interface checks the connection, how long
to wait for a response before the attempt is a failure, and how many consecutive failures
are required before the NXC stops routing to the gateway. The NXC resumes routing to the
gateway the first time the gateway passes the connectivity check.
Enable
Connectivity
Check
Select this to turn on the connection check.
Check Method Select the method that the gateway allows.
Select icmp to have the NXC regularly ping the gateway you specify to make sure it is still
available.
Select tcp to have the NXC regularly perform a TCP handshake with the gateway you
specify to make sure it is still available.
Check Period Enter the number of seconds between connection check attempts.
Check Timeout Enter the number of seconds to wait for a response before the attempt is a failure.
Check Fail
Tolerance
Enter the number of consecutive failures before the NXC stops routing through the
gateway.
Check Default
Gateway
Select this to use the default gateway for the connectivity check.
Check this
address
Select this to specify a domain name or IP address for the connectivity check. Enter that
domain name or IP address in the field next to it.
Check Port This field only displays when you set the Check Method to tcp. Specify the port number to
use for a TCP connectivity check.
DHCP Setting These fields appear when you set the Interface Type to Internal or General.
Table 65 Configuration > Network > Interface > Ethernet > Edit (continued)
LABEL DESCRIPTION