EasyManua.ls Logo

ZyXEL Communications NXC Series - Page 170

ZyXEL Communications NXC Series
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Interfaces
NXC Series User’s Guide
170
Each field is described in the following table.
Table 72 Configuration > Network > Interface > LAG > Add/Edit
LABEL DESCRIPTION
General Settings
Enable Interface Select this to enable this interface. Clear this to disable this interface.
Interface Properties
Interface Type Select one of the following option depending on the type of network to which the NXC is
connected or if you want to additionally manually configure some related settings.
internal is for connecting to a local network. Other corresponding configuration options:
DHCP server and DHCP relay. The NXC automatically adds default SNAT settings for traffic
flowing from this interface to an external interface.
external is for connecting to an external network (like the Internet). The NXC automatically
adds this interface to the default WAN trunk.
For general, the rest of the screen’s options do not automatically adjust and you must
manually configure a policy route to add routing and SNAT settings for the interface.
Interface Name This field is read-only if you are editing the interface. Enter the name of the LAG interface.
The format is lagx, where x is 0 - 3. For example, lag0, lag1, and so on.
PVID A PVID (Port VLAN ID) is a tag that adds to incoming untagged frames received on a port
so that the frames are forwarded to the VLAN group that the tag defines.
Enter the PVID for this port (1~4094).
Zone Select the zone to which the interface is to belong. You use zones to apply security settings
such as security policy, IDP, remote management, anti-virus, and application patrol.
Description Enter a description of this interface. It is not used elsewhere. You can use alphanumeric and
()+/:=?!*#@$_%- characters, and it can be up to 60 characters long.
LAG Configuration
Mode Select a Mode for this LAG interface. Choices are as follows:
active-backup where only one slave in the LAG interface is active and another slave
becomes active only if the active slave fails.
802.3ad (IEEE 802.3ad Dynamic link aggregation) where Link Aggregation Control
Protocol (LACP) negotiates automatic combining of links and balances the traffic load
across the LAG link by sending LACP packets to the directly connected device that also
implements LACP. The slaves must have the same speed and duplex settings.
balance-alb (adaptive load balancing) where traffic is distributed according to the
current load on each slave by ARP negotiation. Incoming traffic is received by the
current slave. If the receiving slave fails, another slave takes over the MAC address of
the failed receiving slave.
Link Monitoring Select from mii or arp.
mii monitoring monitors the state of the local interface; it can’t tell if the link can transmit or
receive packets.
arp monitoring sends ARP queries and uses the reply to know if the link is up and that traffic
is flowing over the link.
Miimom This field displays for mii Link Monitoring. Set the link check interval in milliseconds that the
system polls the Media Independent Interface (MII) to get status.
Updelay This field displays for mii Link Monitoring. Set the waiting time in milliseconds to confirm the
slave interface status is up.
Downdelay This field displays for mii Link Monitoring. Set the waiting time in milliseconds to confirm the
slave interface status is down.
Xmit Hash Policy This field displays in 802.3ad Mode. This field sets the algorithm for slave selection according
to the selected TCP/IP layer.
Rate This field displays in 802.3ad Mode. Select the preferred LACPDU packet transmission rate
(slow/fast) to request from 802.3ad partner.

Table of Contents

Other manuals for ZyXEL Communications NXC Series

Related product manuals