LAYER 3 MODULE TECHNICAL
SPECIFICATIONS
Environmental Requirements
Operating Temperature 0° to 50°C (32° to 122°F)
Storage Temperature 10° to 70°C (14° to 158°F)
Operating Humidity 0 to 95% non-condensing
Environmental Standard EN60068 (IEC 68)
Safety
Agency Certifications UL 1950, EN60950, CSA22.2 No.950, IEC950
EMC
Emissions EN55022 Class B, FCC Part 15 Subpart B Class A, ICES-003 Class A, AS/NZS
3548 Class B, VCCI Class B
Immunity EN50082-1
Power Consumption
Current Rating (@ 5V DC) 7A maximum (35W maximum)
Standards Supported SNMP
SNMP protocol (RFC 1157)
MIB-II (RFC 1213)
BOOTP (RFC 951)
Terminal Emulation
Telnet (RFC 854)
Protocols
IP (RFC 791)
ICMP (RFC 792)
RIP (RFC 1058)
DVMRP (RFC 1075)
IGMP (RFC 1112)
OSPF Protocol Analysis (RFC 1245)
Requirements for IP Version 4 routers (RFC
1812)
Year 2000 Compliance This product is Year 2000 compliant. For information on Year 2000
Compliance and 3Com products, visit the 3Com Year 2000 Web page:
http://www.3Com.com/products/yr2000.html