K-Test Error: Rloop > 7kΩ
The 965DSP checks to see if the resistance of the
loop is less than 7k
Ω. If the resistance is greater
than 7kΩ, then the distance to strap may be too
long, the strap is not connected, or the far-end
switch did not switch properly.
Check the connections, and press [Enter] to repeat
the “Close Far-End” portion of the test.