117
SmartStrap™ Connection
The CTC Smart Strap
Model C1100 supports
Inactive Pair testing only and requires a separate,
good control pair. A Wideband Module Model
C1110W is required for Wideband Autotest. At the
far end of the cable, connect the Control Pair (Pair
0) T and R terminals to the separate control pair
in the cable. Connect the test pair tip conductor to
the T terminal of Pair 1 (or higher) on the Smart
Strap module and the test pair ring conductor to the
R terminal of the same pair. Connect the Ground
terminal to ground. Turn on the Smart Strap. Refer
to the CTC Smart Strap
Operator’s Manual for
more information.
Dead Pair Test
Red Lead
SmartStrap
C1100
Black Lead
Blue Lead
Yellow Lead
Green Lead
T
R
T
R
T
R
T
R
Ground
3 Test Pair
2 Test Good Pair
1 Good Pair
0 Control Pair