RFL Errors
One of several errors may occur during an RFL
multi-section measurement.
If the RFL measurement terminates due to a time-
out, a “Yield Sign” will be displayed next to the
DSTF or RSTF result, as shown. This indicates
that the results may not be accurate. This could be
caused by excessive noise on the pair.
The multi-section screen will now show the
computed length of the unknown section.
Use [Tab] to convert between Ohms and Distance.
Use [Setup] to display the RFL Multi-Section Setup
screen again.