EasyManuals Logo

ABB 2600T Series Operating Instructions

ABB 2600T Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
48 OI/266/PB-EN Rev. E | 2600T Series Pressure transmitters
14 Device Block Diagram
MODE
TARGET_MODE
AUTO
Transfer
Function
LIN_TYPE = Linear
PV_SCALE
PV_SCALE_100%
PV_SCALE_0%
PRIMARY_VALUE_UNIT
OUT_SCALE
OUT_SCALE_100%
OUT_SCALE_0%
OUT_SCALE_UNIT
OUT_SCALE_DEC
OUT (5)
[OUT_SCALE_UNIT]
CHANNEL
Damping
PV_FTIME
Limits
ALARM_HYS
HI_HI_LIM
HI_LIM
LO_LIM
LO_LO_LIM
Pressure
Transducer
Block
PV
SP
TMP
Simulation
SIMULATE_ENABLE
SIMULATE_VALUE
SIMULATE_STATUS
Operator
Fail Safe
FSAFE_TYPE
FSAFE_VALUE
Operator
OUT
MAN
OUT
FSAFE_VALUE
O/S
FIELD_VAL = (CHANNEL_VAL PV_SCALE_0%) / (PV_SCALE_100% - PV_SCALE_0%)
PV = FIELD_VAL * (OUT_SCALE_100% - OUT_SCALE_0%) + OUT_SCALE_0%
to HMI
ANALOG INPUT BLOCK

Table of Contents