Technical data 123
DC connection
Voltage 243…356 V DC (ACS880-M04-xxxx-2 drives)
436…743 V DC (ACS880-M04-xxxx-5 drives)
Ratings, fuse
recommenda-
tions
Terminals Frame R1: Detachable screw terminal block for 0.25…4 mm
2
wire.
Frame R2: Detachable screw terminal block for 0.5…6 mm
2
wire.
Frames R3 and R4: Screw lugs for 6…70 mm
2
wire included. Suitable
crimp lugs can be used instead.
Drive
type
ACS880-
M04
-xxxx-2/5
I
dcN
C IEC fuse UL fuse
(A) (µF) Rated
current
(A)
Voltage
(V)
Class Rated
current
(A)
Voltage
(V)
Class
-03A0 3.3 120 16 690 aR 12 690 URC
-03A6 3.9 120 16 690 aR 12 690 URC
-04A8 4.8 240 16 690 aR 12 690 URC
-06A0 6.5 240 16 690 aR 12 690 URC
-08A0 8.7 240 16 690 aR 12 690 URC
-010A 12 370 20 690 aR 16 690 URC
-014A 15 740 32 690 aR 32 690 URD
-018A 20 740 32 690 aR 32 690 URD
-025A 29 670 63 690 aR 63 690 URQ
-030A 38 670 63 690 aR 63 690 URQ
-035A 44 1000 100 690 aR 100 690 URQ
-044A 54 1000 100 690 aR 100 690 URQ
-050A 54 1000 100 690 aR 100 690 URQ
-061A 73 1340 160 690 aR 160 690 URQ
-078A 85 2000 160 690 aR 160 690 URQ
-094A 98 2000 160 690 aR 160 690 URQ
I
dcN
Average DC input current requirement when running a typical induction motor
at P
N
at a DC link voltage of 540 V (which corresponds to an AC input voltage
of 400 V).
C Capacitance of DC link.