124 Technical data
Motor connection
Motor types Asynchronous induction motors, permanent magnet motors, ABB
synchronous reluctance motors
Frequency 0…500 Hz
Current See section Ratings.
Switching
frequency
3 kHz (default)
Maximum motor
cable length
Frames R1 and R2: 150 m (492 ft)*
Frames R3 and R4: 300 m (984 ft)*
*100 m with EN 61800-3 Category C3 filter
Terminal s Frame R1: Detachable screw terminal block for 0.25…4 mm
2
wire.
Frame R2: Detachable screw terminal block for 0.5…6 mm
2
wire.
Frames R3 and R4: Screw lugs for 6…70 mm
2
wire included. Suitable
crimp lugs can be used instead.