EasyManua.ls Logo

ABB ACS880-M04 - STO Data; Safety Data; Temperature Profile for Safety Value Calculations; STO Indication Data

ABB ACS880-M04
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Safe torque off function 153
STO data
Safety data
The safety data for the Safe torque off function is given below.
Note: The safety data is calculated for redundant use, and does not apply if both STO
channels are not used.
Temperature profile for safety value calculations
STO indication data
Frame
size
SIL/
SILCL
SC PL SFF PFH
D
(T
1
= 20 a)
PFD
(T
1
= 2 a)
MTTF
d
DC Cat. HFT CCF Life
time
(%) (1/h) (a) (%) (a)
R1 to
R4
3 3 e 98.8 3.23E-09 2.99E-06 24293
>
90 3 1 80 20
T
Number of on/off cycles per year
71.66 °C 670 cycles
61.66 °C 1340 cycles
10.0 °C 30 cycles
Board temperature
% of time
32 °C 2.0%
60 °C 1.5%
85 °C 2.3%
Safety component Type A, as defined in IEC 61508-2
STO reaction time
(shortest detectable break)
1ms
STO response time Frame sizes R1…R4: 2 ms (typical), 5 ms (maximum)
Fault detection time Channels in different states for longer than 200 ms
Fault reaction time Fault detection time + 10 ms
STO fault indication
(parameter 31.22) delay
<500ms
STO warning indication
(parameter 31.22) delay
<1000ms

Table of Contents