176 Resistor braking
P
brcont =
The drive (drive and chopper) withstands this continuous braking power. Braking is
considered continuous if braking time exceeds 30 seconds.
P
brmax
= Maximum braking power of the drive (drive and chopper). The drive (drive and
chopper) withstands this braking power for 1 second within every 10 seconds.
Note: The listed resistors withstand this braking power for 1 second within every 120 seconds.
R
min =
The minimum allowed resistance of the brake resistor.