II K 4-63
Overview of Software
ParNo. Parameter name and significance Min Max Default Unit (1)
custom.
setting
Grp 6 Input / Output (continued)
6.20 Dataset 2.2 Asn
Selection of the desired assignment for fieldbus
dataset 2.2:
0 = Speed Act / speed actual value (5.05)
1 = Speed Ref / speed reference value (5.04)
2 = Arm Volt Act / armature voltage act. value (3.03)
3 = Arm Cur Ref / armature current ref. val. (3.01)
4 = Arm Cur Act / armature current act. value (3.02)
5 = Power Act / actual power (3.21)
6 = Torque Act / torque actual value (3.23)
7 = Fld Cur Act / field current actual value (4.02)
8 = Dataset 3.2
9 = Dataset 3.3
10 = AI1 Act / Analogue Input 1 actual value (6.26)
11 = AI2 Act / Analogue Input 2 actual value (6.27)
12 = Ramp In Act / Speed ref. at ramp gen. input (5.33)
0 12 0 Text
6.21 Dataset 2.3 Asn
Selection of the desired assignment for fieldbus
dataset 2.3:
Assignment identical with Dataset 2.2 Asn (6.20)
0 12 4 Text
(1) no chan