Cleaning methodProtection
type
High pressure water or
steam
Rinse with waterWipe with clothVacuum
cleaner
NoYes. It is highly re-
commended that
the water contains
a rust-prevention
solution.
Yes. With light
cleaning deter-
gent or spirit.
YesFoundry Plus
NoNoYes. With light
cleaning deter-
gent, spirit or
isopropyl alco-
hol.
YesClean room
Cleaning with water and steam
Instructions for rinsing with water
IRB 1300 with protection class IP67 (option) and with protection type Foundry Plus
can be cleaned by rinsing with water (water cleaner).
1
The following list defines the prerequisites:
Maximum water pressure at the nozzle: 700 kN/m
2
(7 bar)
I
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum flow: 20 liters/min
I
I
Typical tap water pressure and flow
Cables
Movable cables need to be able to move freely:
Remove waste material, such as sand, dust and chips, if it prevents cable
movement.
Clean the cables if they have a crusty surface, for example from dry release
agents.
1
See Cleaning methods on page 106 for exceptions.