Loading...
NoteAction
Small circular plate of the axis-2
sealing assembly tool, included in
Special toolkit for IP67/Clean
Room/Foundry Plus robots
(3HAC078203-001).
xx2000002470
Fit the small circular plate of the axis-2 sealing
assembly tool and fix with three M6x75 screws.
7
xx2000002471
Screw the screws, little by little and evenly, to
press the sealing into place.
8
Remove the assembly tool.9
Check that the sealing is undamaged and properly
fitted.
10
Refitting the swing support
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Sealing ring, swing support side:
3HAC065676-001
Check the sealing ring.
Replace if damaged.
2
Screw: M4x12 12.9 Lafre
2C2B/FC6.9 (16 pcs)
Tightening torque: 3.8 Nm