NoteArticle numberSpare part
Used with protection classes IP40
and IP67.
Used with protection type
Foundry Plus.
3HAC073093-001Housing cover
Used with protection classes IP40
and IP67.
Used with protection type
Foundry Plus.
3HAC073092-001Lower arm cover
Used with protection type Clean
Room.
3HAC077823-001Tubular cover, Clean Room
Used with protection type Clean
Room.
3HAC077822-001Housing cover, Clean Room
Used with protection type Clean
Room.
3HAC077821-001Lower arm cover, Clean Room
Not used with protection class
IP40.
Replace if damaged.
3HAC070887-001Gasket for process hub
Not used with protection class
IP40.
Replace if damaged.
3HAC067834-001Gasket for tubular cover
Not used with protection class
IP40.
Replace if damaged.
3HAC067833-001Gasket for housing cover
Not used with protection class
IP40.
Replace if damaged.
3HAC067826-001Gasket for lower arm support
Not used with protection class
IP40.
Replace if damaged.
3HAC067832-001Gasket for lower arm cover
Not used with protection class
IP40.
Replace if damaged.
3HAC032050-001Seal bolt
Not used with protection class
IP40.
Replace if damaged.
3HAC070148-005Radial sealing on lower arm
Used with protection types Clean
Room and Foundry Plus.
Replace if damaged.
3HAC070148-006Radial sealing on housing
Not used with protection class
IP40.
Replace if damaged.
3HAC061327-018O-ring on tubular
Not used with protection type
Clean Room.
Replace if damaged.
3HAC078352-001Plug screw
Used with protection type Clean
Room.
Replace if damaged.
3HAC078351-001Plug screw, Clean Room
Continues on next page
362 Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit