Removing the extender unit
Note
Only IRB 1300-7/1.4 and IRB 1300-12/1.4 have an extender unit, connecting the
housing and tubular.
Use these procedures to continuously remove the extender unit after removing
the housing.
Removing the axis-4 mechanical stop flange
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 145.
2
xx2000001673
Remove the axis-4 mechanical stop flange.
CAUTION
The axis-4 mechanical stop slider is accessible
from the housing.
Put it aside for later refitting.
xx2000001674
3
Continues on next page
Product manual - IRB 1300 381
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit
Continued