Refitting the axis-4 mechanical stop slider
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000001732
Place the axis-4 mechanical stop slider in the
housing.
2
Refitting the housing
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
O-ring on tubular: 3HAC061327-
018
xx2000002519
For robots with protection class IP67 (option
3350-670)
For robots with protection type Clean Room
(option 3351-4)
For robots with protection type Foundry Plus
(option 3352-10)
Valid for IRB 1300-11/0.9 and IRB 1300-10/1.15
Check the O-ring.
Replace if damaged.
2
xx2000001734
Refit the tubular to the housing.3
Continues on next page
Product manual - IRB 1300 455
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued