Refitting the axis-6 motor
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
• all assembly surfaces are clean and without
damages
• the motor is clean and undamaged.
2
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx2000001603
Orient the motor correctly and fit it into the tubular.
Tip
Leave the axis-6 motor connectors accessible
from the tubular support side.
3
Screw: M5x16 12.9 Lafre
2C2B/FC6.9 (4 pcs)
xx2000001601
Refit the screws and washers.
Note
Do not tighten the screws yet.
4
Refitting the axis-6 timing belt
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000001600
Install the timing belt to the pulleys and verify that
the belt runs correctly in the grooves of the pul-
leys.
2
Continues on next page