NoteAction
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the second semicircular bracket to the tubu-
lar.
2
Tightening torque: 2.6 Nm
xx2000001749
Route the cablings.
Leave the CP/CS connectors and motor
connectors out from the tubular support,
and Ethernet connectors and air hoses out
from the process hub.
The air hoses are facing upside in the
semicircular bracket.
3
Reconnecting the air hoses and Ethernet cabling (if equipped)
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000001539
Reconnect the air hoses.
Note
See the number markings on the air hoses for
help to find the corresponding air hoses.
2
xx2000001540
For robots with Ethernet cabling
Access the connector from the process hub and
reconnect the connector.
J1.C2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Continues on next page
480 Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued