Note/IllustrationAction
Screws: Torx, countersunk screw M4x10 (4
pcs)
Insert the HMI signal connector into the
cover from inside the cabinet.
3
Tightening torque: 1.7 Nm±10%.Secure it with the screws.
xx2100000832
Reconnect any connectors disconnected
at removal.
4
Secure the cables on HMI signal connect-
or with new cable ties.
Tip
Use the same position as from removing
the HMI signal connector.
5
xx2300001847
Refit the cover plate.6