Operation Manual / Power2 800-M / 4 Product description
Page 37 /
© Copyright 2016 ABB. All rights reserved.
Figure 14: Cover grid connecting rods
81272 20
81273 40
Table 15: Tightening torque (81272) / (81273)
Connect the connecting rods (81269) with the screws (81272). While tightening the screws
(81272), make sure that the connecting rods (81269) lie correctly in the slots on the filter
silencer body (81135). Now alternately tighten the screws (81272) up to the maximum
tightening torque shown above.
Fit lock nuts (81273) to screws (81272) and tighten with the tightening torque shown
above:
Fit the filter ring (81265), if present.