Operation Manual / Power2 800-M / 4 Product description
7
Troubleshooting
Page 41 /
59
© Copyright 2016 ABB. All rights reserved.
HZTL4061_EN
Revision A
September 2016
Increase in low-pressure stage speed
Possible causes
Remedy
Low-pressure
stage
Heavy contamination of the nozzle
ring
Contact ABB Turbocharging Service Sta-
tion
Table 22: Malfunctions during operation Power2 LP speed increases
Increase in high-pressure stage speed
Possible causes
Remedy
High-pressure
stage
Heavy contamination of the nozzle ring Contact ABB Turbocharging Service Sta-
tion
Low-pressure stage defective Contact ABB Turbocharging Service Sta-
tion
Pipes Leak in exhaust gas pipe before the
low-pressure stage
Repair
Table 23: Malfunctions during operation Power2 HP speed increases
Exhaust gas temperature too high
Engine performance and engine speed unchanged
Possible causes
Remedy
Engine Malfunction in the injection system Repair or contact manufacturer
Low-pressure or
high-pressure
stage
Insufficient air, for example, because
filter silencer is blocked by contamina-
tion
Clean
Compressor/turbine contaminated
Exhaust gas back pressure too high
Clean or repair boiler or exhaust gas si-
lencer
Turbine damaged or eroded Contact ABB Turbocharging Service Sta-
tion
Charge air cool-
er/intercooler
Cooler contaminated
Clean
Cooling water volume too low Fill
Inlet temperature of cooling water too
high
Check/clean cooling system
Insufficient ventilation Improve ventilation
Table 24: Malfunctions during operation Exhaust gas temperature too high