― 33 ―
→Selected in TYPE 3116/3116A
Handling of an option article
Detail Specification of Communication Command
1.Interface
RS-232C(asynchronous)
Data size ;8bit
Stop bit ;1it
Parity check ;non
Transfer Speed ;4800,9600,19200bps
Flow control ;non
2.Data Specification
All the data are outputted in ASC II format.
The PC software needs ‘Time Out’ function.
① 001/256 + LF :Measurement No.
② 05/07/05□16:15 + LF :Measurement date
③ 120.2m/s
2
□RMS+LF + LF :Data
・
・
① 002/256 + LF
② 05/07/05□16:15 + LF
③
02.02m/s
2
□RMS+LF + LF
<Explanation>
① Measurement No.・Saving measurement data
(Maximum number of saving measurement data:256) → (001/256 ~256/256)
ex) In the case of ten data : 001/010 Starting with ---
002/010
・
・
010/010 ,and ends.
② Calendar for Measuring Time and Date
year/month/day hour:minute
③ Data mode
<Numeric data>
2000
200.0
20.00
<Measurement mode>
m/s
2
(Acceleration)
μm (Displacement)
mm/s(Velocity)
<Data mode>
Peak
RMS
EQPaek
EQ
P-P
□ :Space (20)
+LF :Line feed code(0A)