Fault title on
display
Fault code System Fault level System condition
description
Needles not home 520910 Knotter system High Baler is in operation
and the needles
have been away
from the start
position for more
than 1 flake.
The needles are not
at the start position
on startup.
Tie cycle fault 520912 Knotter system High After the knotter was
set to ON, the
machine did not get
a signal that the tie
cycle started:
-2 times in automatic
mode.
-1 time in manual
mode.
Bale oversize 520914 Knotter system Low The current bale
length is equal to or
more than 100 mm
(3.9 in) over the set
bale length.
Knotter fan forward
relay fault
520915 Knotter system Low Module
configuration and
standard output
fault.
Knotter fan reverse
relay fault
520917 Knotter system Low Module
configuration and
standard output
fault.
Flywheel shearbolt
failure
521008 Drives/Gears High The PTO speed
decreased faster
than the approved
value for the
machine.
No PTO speed
detected
521009 Drives/gears Low The PTO speed
signal is lower than
100 rpm, but the
machine is in
operation and it
makes bales.
5 Troubleshooting
94
SimplEbale