Fault title on
display
Fault code System Fault level System condition
description
Moisture system
fault
520501 Moisture system Low The moisture system
is set to ON and:
There is no
communication
from the moisture
sensor for 3
seconds.
The system type
data is unknown.
There is a 30
second
configuration
delay.
Moisture system
fault
520501 Moisture system Low The moisture
function is OFF and
the machine can not
find the moisture
system.
Scale module fault 520701 Chute scale Low The scale function is
OFF and the
machine can not find
the Load Sensor
Module (LSM)
system.
Insufficient load cells 520702 Chute scale Low Load Sensor Module
(LSM) is ON and the
system senses that
there are less than
or more than 3 load
cells.
Bale length sensor
fault
520901 Knotter system High Standard analog
input fault.
Knotter trip relay
fault
520905 Knotter system High Standard output
fault.
Continuous needles
cycling
520909 Knotter system High Baler is in operation
and on the twine tie
cycle the start flake
count of the bale is
less than 1.
5 Troubleshooting