Using Setup Features
6-6 Setup and Advanced Mode Features
Using Setup Features
NOTE: To move around the menus displayed, use the Option buttons as follows:
Press the LOWER Option button to move the highlight bar from one item to
another on the menu.
Press the UPPER Option button to select the highlighted item or to scroll through
the settings for that item.
The HEARTSTREAM FR2 comes with a factory default setup designed to meet
the needs of most users. The setup feature of the FR2 lets you review the
current setup of your H
EARTSTREAM FR2 or install a revised setup if
appropriate. To go to the SETUP menu:
1. Remove and reinstall the battery to bring up the first menu on the screen.
NOTE: This screen will not be displayed if the defibrillation pads are connected to
the FR2 when the battery is inserted, and you will not be able to access the menu
items. In addition, the battery insertion selftest and periodic automatic selftests cannot
run while the defibrillation pads are connected. Be sure to unplug the pads connector
from the FR2 after each use. Do not store the FR2 with the pads connected.
2. Within 10 seconds of installing the battery, press the lower Option button
to move the highlight bar to NEXT.
3. Press the upper Option button to select NEXT.
4. Press the lower Option button to move the highlight bar to SETUP.
5. Press the upper Option button to bring up the SETUP menu
The SETUP menu allows you to receive setup directly from another
H
EARTSTREAM FR2 or a computer running CODERUNNER software, read
setup from a data card, or review current setup.
Reviewing Current Setup
A good way to understand the setup of your FR2 is to review the setup it
currently uses.
1. Select REVIEW SETUP from the SETUP menu. The first of a series of
REVIEW SETUP screens is displayed.
RUN SELFTEST
REVIEW INCIDENT
NO DATA CARD
GOOD BATTERY
NEXT
IN EMERGENCY
PRESS OFF TO QUIT
DEVICE HISTORY
BATTERY HISTORY
SETUP
CLOCK
RETURN
IN EMERGENCY
PRESS OFF TO QUIT
SETUP
RETURN
RECEIVE SETUP
READ SETUP
REVIEW SETUP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies M3860A and is the answer not in the manual?

Agilent Technologies M3860A Specifications

General IconGeneral
BrandAgilent Technologies
ModelM3860A
CategoryMedical Equipment
LanguageEnglish

Related product manuals