NovoCyte Quanteon Flow Cytometer
Operator's Guide
For Research Use Only. Not for use in diagnostic procedures.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies NovoCyte Quanteon and is the answer not in the manual?

Agilent Technologies NovoCyte Quanteon Specifications

General IconGeneral
BrandAgilent Technologies
ModelNovoCyte Quanteon
CategoryLaboratory Equipment
LanguageEnglish

Summary

Prologue

Using this Guide

This guide describes the information and procedures to install, operate, maintain, and troubleshoot NovoCyte Quanteon flow cytometer and associated standard accessories.

Symbols

The following table lists the symbols which may be used in this guide.

Introduction

Overview

This chapter provides overview of NovoCyte Quanteon flow cytometer, including basic instrument operation principle, system requirements, and system components.

Optics System

The optics system consists of lasers, optical lenses, beam shaping optics, light collection optics, optical filters, and photodetectors.

Fluorescence Compensation Theory

Explains spectral overlap and the need for fluorescence compensation.

Fluidics System

Describes the components of the fluidics system.

Electronics System

Describes the electronics system and signal processing.

System Requirements

Details software, workstation, and fluidics station requirements.

System Components

Lists the main system components including the instrument, fluidics station, and workstation.

Installation

Installation Warnings

Lists critical warnings and precautions for instrument installation.

Space Requirements

Specifies the minimum space needed for installation.

Environmental Requirements

Outlines the recommended operating and storage environmental conditions.

Instruction for Lifting and Carrying

Provides guidance on safely moving and handling the instrument.

Connect NovoCyte Workstation

Details how to connect the workstation to the instrument and monitor.

Connect NovoCyte Fluidics Station II

Explains how to connect the fluidics station to the instrument.

Connect Instrument to Power Supply

Details how to connect the instrument to the power supply.

Instrument Operation

Instrument Start-up

Guides through the initial steps to power on and prepare the instrument.

Add Instrument Reagents

Provides instructions for refilling reagent containers.

Empty Waste

Guides on how to empty the waste container.

Verify and Modify Instrument Configuration

Explains how to check and customize the instrument's optical configuration.

Instrument QC Test

Explains the purpose and procedure for instrument quality control.

Instrument Shutdown

Guides on how to properly shut down the instrument.

Running Samples

Overview

Describes the example test using peripheral blood lymphocytes.

Create Experiment

Guides on creating a new experiment file in NovoExpress software.

Define Sample Acquisition Parameters

Details how to set detection parameters and channel aliases.

Set Sample Acquisition Conditions

Explains how to set stop conditions, flow rate, and thresholds.

Run Sample

Guides on how to initiate sample acquisition.

Perform Fluorescence Compensation

Explains automatic and manual methods for fluorescence compensation.

Analyze Data

Introduces data analysis tools and plots in NovoExpress software.

Import and Export Files

Details manual and automatic methods for exporting data files.

System Maintenance

Scheduled Maintenance

Lists routine maintenance tasks and their recommended frequency.

Preventive Maintenance

Outlines monthly preventative maintenance procedures for optimal system condition.

Replacing Fluidic System Consumables

Guides on replacing fluidic system consumables when prompted.

Unscheduled Maintenance

Lists maintenance tasks performed as needed based on specific conditions.

Debubble

Explains the debubble procedure for removing air bubbles.

Decontamination

Details the decontamination procedure for the fluidics system.

Calibrate NovoCyte Fluidics Station II

Explains how to recalibrate the fluidics station.

Clean Fluidic System

Procedure to clean the flow cell or sampling tubing.

Troubleshooting

Instrument QC test fails

Addresses issues when the instrument QC test fails.

Zero or low number of events detected

Troubleshoots scenarios with few or no detected events.

Excessive debris in display

Troubleshoots excessive debris appearing in the data display.

NovoExpress displays Instrument not connected

Addresses issues when NovoExpress shows instrument as not connected.

Leakage from the SIP

Troubleshoots leakage issues originating from the SIP.

Version History

History of updates

Lists the version history of the manual.

Appendix A: NovoCyte Quanteon Laser and Detection Channel Configuration

Laser Configuration

Details the laser wavelengths and detectable fluorochromes.

Detection Channel Configuration

Lists optical filters and recommended fluorochromes for each detector.

Appendix B: NovoCyte Quanteon Technical Specifications

NovoCyte Quanteon Technical Specifications

Lists optics, laser, and fluidics specifications.

NovoCyte Workstation and Monitor Specifications

Lists specifications for the workstation and monitor.

NovoCyte Fluidics Station II Specifications

Lists specifications for the fluidics station.