Use and Maintenance Manual - X_RT Series Page 36
5.1.6.7 Warning lights
5.1.6.8 Enabled control panel green warning light (O)
On with flashing light when the machine is turned on. If the platform control panel has been selected and this light flashes the controls
are not enabled because the dead-man button was not pressed or more than 5 seconds went by since its release and no operation
was performed.
On steady
with machine on and dead-man button pressed for less than 5 seconds. With platform control panel all controls are enabled
(unless other types of warning show up – see next paragraphs).
5.1.6.9 Sliding platform position green warning light (P - only for machines with sliding platform - NOT
AVAILABLE)
This light is present on machines fitted with sliding platform (the whole platform can slide longitudinally).
When sliding platform is not in central position, the warning light is OFF, and only platform extension/retraction is possible.
When it is ON, the sliding platform is in central position, and the machine operation can be resumed (unless other warnings – see
next/previous paragraphs).
5.1.6.10 Flat battery red warning light (Q – only Electric and Electro/diesel models)
Flashing
when the battery charge is at 20% (only models "E" or "ED" with current continuous electric pump). In this condition, platform lifting
is disabled. Batteries should be immediately recharged.
5.1.6.11 Drive enable green warning light (R)
This light is ON when drive can be carried out. Drive movement is inhibited (green light OFF) when:
a) One or more levelling outriggers are not completely retracted (did not reach the upper end stop).
See also warning lights ZB
– only machines with levelling outriggers.
b) Platform is above the maximum drive height (see paragraph “Technical features”).
c) Sliding platform is “out of center”.
See also green warning light P – only machines with sliding platform.
d) With lifted platform the machine is on a ground inclined over the max. allowed inclination. See warning lights S and T.
e) With lifted platform, the platform is overloaded.
See warning lights U and T.
f) With the platform raised, the oscillating axle is locked in an inclined position.
See also warning light S.
P
Q
R T
U
B