5.5 Machine stop
5.5.1 Normal stop
During the normal stop of the machine, if you release the controls, the operation is stopped. Stop occurs within a time limit set in
the factory, which guarantees smooth braking.
5.5.2 Emergency stop button
Should it be necessary, the operator may immediately stop all machine functions on both platform and ground control panel.
On the platform control panel:
Press the emergency stop button on the control panel and the machine is turned off.
On the ground control panel:
Press the emergency stop button and the machine (all models) and the heat engine (models “D”, “ED”, “EB”) are stopped.
By pressing the power emergency stop button, thus cutting out machine power (power circuit cut-out).
To resume the operations:
On the platform control panel:
Turn the emergency stop button of 1/4 turn clockwise.
On the ground control panel:
Turn the emergency stop button of 1/4 turn clockwise.
Turn clockwise the red knob of the power circuit a 1/4 turn up to the complete engagement to restore the power supply to
the machine.
5.5.3 Diesel engine stop
In order to stop the Diesel engine:
On the platform control panel:
Turn the starting key anticlockwise to "0" position.
Otherwise, press the emergency stop button.
On the ground control panel:
Turn the starter key anticlockwise to position “0”.
Otherwise, press the emergency stop button.
Do not stop the motor when the r.p.m. is high. Before stopping the engine wait until the r.p.m. is at the lowest.