Use and Maintenance Manual - X_RT Series Page 39
5.2.1 On-off key and control panel selector (A)
The on-off key located on the ground control panel is used to:
turn ON the machine by selecting one of the two control panels:
Platform controls enabled with locking key switch set to “platform” symbol. Stable key position with possibility to extract the
key.
Ground controls enabled (for emergency operations) with key switch set to “chassis” symbol. Position with action to be
kept. When the key is released the machine is turned off.
Turn OFF the control circuits by turning it to OFF.
5.2.2 Emergency STOP button (B)
By pressing this button the machine (as well as the heat engine on models "D", "ED" and "EB") is completely stopped. By rotating it
of 1/4 turn (clockwise) the machine can be turned ON by means of the ON-OFF key.
5.2.3 Diesel/electric drive power selector (C)
Holding the ON-OFF key in position “ground controls” it is possible to select the type of drive power for the ground controls:
If ELECTRIC is selected and the ON-OFF key is kept active in position “ground controls” the electric pump is started while
operating the ground controls.
If DIESEL is selected and the ON-OFF key is kept active in position “ground controls” the Diesel engine can be started.
5.2.4 Heat motor start button (D)
Holding the ON-OFF key in position “ground control panel” after selecting the DIESEL power, the diesel engine can be started by
means of the relevant switch.
In “0” position the Diesel engine is off.
In “3 sec” position the plugs pre-heating takes place (only for engines with plugs).
In “Start” position the motor starts.