7.1 Safety lock for maintenance operations
Before carrying out any maintenance or repairs to it,
activate the lifting structure locking system.
Watch the pictures aside to understand how the lifting
locking structure works before carrying out any
maintenance or repairs to it.
Unscrew knobs B completely (on both sides of the lifting
structure).
Rotate safety bars A by setting them in vertical position.
Lower the structure until it rests on bars A firmly.
Check the correct positioning of bars A.
Fig. 19
7.2 Machine cleaning
To clean the machine use non-pressurized water jets after properly protecting the following parts:
The control panel (both platform and ground).
The electric ground control unit and all electric boxes in general.
The electric motors.
Do not use pressurized water jets (high-pressure cleaners) to clean the machine.
After washing the machine, always:
Dry the machine.
Check integrity of plates and stickers.
Lubricate the articulated joints equipped with greaser and the sliding ways.