Use and Maintenance Manual - X_RT Series Page 40
5.2.5 User interface display (E)
The multifunction display for machine/user interface is used to:
Display the operation parameters of the machine during normal functioning or in the event of a fault;
Working hours of Diesel engine (when Diesel power is selected the working hours are displayed in the format HOURS:
MINUTES and final letter D).
Working hours of the electric pump (when electric power is selected the working hours are displayed in the format
HOURS:MINUTES and final letter E).
Charge level of the battery (only electrical models E).
The user interface display is also used during any interventions by specialized personnel to calibrate/adjust
the working parameters of the machine. This function is not available to the user.
5.2.6 Battery charger warning light (F)
Electric- and dual-powered models (“E”, “ED” and “EB”), equipped with a built-in high frequency battery charger, are provided with
this warning light indicating the operation of the battery charger (for more detailed information read the paragraph "Battery charge”).
5.2.7 Enabled control panel warning light (G)
The green light is ON when the machine is turned ON and the ground control panel is enabled (the on/off key (C) should be kept in
chassis position).
5.2.8 Diesel engine warning lights (H-L-M-N)
These warning lights warn the user of any Diesel motor operational faults (models “D” and “ED”). One of these warning lights turns
ON when the motor is stopped. A “fault” message is sent to the operator on the platform (see paragraph “Platform control panel”)
Once the Diesel motor has stopped due to a problem signalled by one of these warning lights, the motor can no longer be re-
started until such problem has been solved.
5.2.9 Platform lifting/lowering lever (O)
This lever is to be used to lift or lower the platform. This control can be operated only if the on-off key is set to ON downwards
(ground control panel selected). We shall also remind you that the ground controls are to be used to operate the platform only in
emergency situations and must not be used for any other purposes.
Use the ground controls only in emergency situations to allow the platform to be lowered.
IT IS FORBIDDEN to use the ground control panel as a workstation when personnel is on the platform.
5.2.10 Movement alarm
The machine has an audible alarm that is activated as follows:
- Always with intermittent sound, every 2 seconds approx., to indicate any movement of the machine.
- With intermittent sound every 0.5 seconds to indicate the danger of being trapped in the lifting structure during the last
section of the lowering movement (see par. "Platform lifting/lowering").

Table of Contents