System Management
7210 SAS M, X Basic System Configuration Guide Page 285
System Alarm Contact Commands
alarm-contact-input
Syntax alarm-contact-input alarm-contact-input-id
Context config>system>alarm-contact-input
Description This command provides the context to configure one of four available alarm contact input pins.
Default None
Parameters alarm-contact-input-id — Identifies the alarm contact input pin.
Values 1 — 4 (for SAS M only)
Values 1— 3 (for SAS X only)
alarm-output-severity
Syntax [no] alarm-output-severity {critical | major | none} (for SAS M only)
[no] alarm-output-severity {critical | major | minor | none} (for SAS X only)
Context config>system>alarm-contact-input
Description This command allows the user to relay alarms from the alarm-contact input to the alarm-contact
output by associating an appropriate alarm-contact output with the alarm-contact input. The system
generates or clears the alarm-contact output when it triggers or clears the alarm for the associated
alarm-contact input.
If multiple alarm-contact input pins share an alarm-contact output, the system generates the alarm-
contact output even if any one of the alarm-contact input is triggered and the system clears alarm-
contact output only when all the alarm-contact input pins are cleared.
The severity parameter configured by the user determines the appropriate alarm-contact output to be
used for generation and clearing the alarm.
Note: The system relays the alarm-contact input to the appropriate alarm-contact output only if the
alarm-contact output is available on the platform.
Default Major
Parameters critical — A critical alarm output is generated or cleared.
major — A major alarm output is generated or cleared.
minor — A minor alarm output is generated or cleared.
none — No alarm output is generated or cleared.