System Alarm Contact Commands
Page 286 7210 SAS M, X Basic System Configuration Guide
clear-alarm-msg
Syntax [no] clear-alarm-msg {alarm-msg-text}
Context config>system>alarm-contact-input alarm-contact-input-id
Description This command allows the user to configure a text message for use along with SNMP trap and Log
message that are sent when the system clears an alarm. The system generates a default message if the
message is not configured. The system does not generate a trap or log if no form of the command is
enabled.
Default None
Parameters alarm-msg-text — A printable character string, up to 160 characters in length.
description
Syntax description description-string
Context config>system>alarm-contact-input alarm-contact-input-id description
Description This command describes an alarm contact input pin. The description provides an indication of the
usage or attribute of the pin. It is stored in the CLI configuration file and helps the user in identifying
the purpose of the pin.
Default None
normal-state
Syntax normal-state [open | closed]
Context config>system>alarm-contact-input alarm-contact-input-id
Description This command configures the normal state to be associated with the alarm-contact input. When the
system detects a transition from the normal state, an alarm is generated. The alarm is cleared when the
system detects a transition is back to the normal state.
Default closed
Parameters open — The normal-state is identified as ‘open’. When the system detects a transition to the ‘closed’
state, an alarm is generated. The alarm is cleared when the system detects a transition back to the
‘Open’ state.
closed-state — The normal-state is identified as ‘closed’. When the system detects a transition to
the‘open’ state, and alarm is generated. The alarm is cleared when the system detects a transition
back to the ‘closed’ state.

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals