System Commands
Page 320 7210 SAS M, X Basic System Configuration Guide
Sample Output
*A:7210-SAS>show>system# sync-if-timing
===============================================================================
System Interface Timing Operational Info
Admin Status
Indicates the Admin status of reference input 1.
down — Indicates the ref1 or ref2 configuration is administratively
shutdown.
up — Indicates the ref1 or ref2 configuration is administratively
enabled.
diag — Indicates the reference has been forced using the force-refer-
ence command.
Qualified For Use
Indicates if the reference input 1 is qualified for use
Selected For Use
Indicates if reference input 1 is selected for use
Source Port
Displays the source port information
Reference Input 2
Displays information about reference input 2
Admin Status
Indicates the Admin status of reference input 2.
down — Indicates the ref1 or ref2 configuration is administratively
shutdown.
up — Indicates the ref1 or ref2 configuration is administratively
enabled.
diag — Indicates the reference has been forced using the force-refer-
ence command.
Qualified For Use
Indicates if the reference input 2 is qualified for use.
Selected For Use
Indicates if reference input 2 is selected for use
Not Selected Due To
Indicates the reason if reference input 2 is not selected.
Source Port
Displays the source port information
Quality Level Selec-
tion
Indicates whether the ql-selection command has been enabled or dis-
abled. If this command is enabled, then the reference is selected first
using the QL value, then by the priority reference order. If this com-
mand is not enabled, then the reference is selected by the priority refer-
ence order.
System Quality Level
Indicates the quality level being generated by the system clock.
Rx Quality Level
Indicates the QL value received on the interface.
• inv - SSM received on the interface indicates an invalid code for
the interface type.
• unknown - No QL value was received on the interface.
Label Description (Continued)