7705 SAR OS System Management Guide Page 225
ALU-12>config>log# info
#------------------------------------------
echo "Log Configuration"
#------------------------------------------
throttle-rate 500 interval 10
event-control "atm" 2014 generate critical
event-control "oam" 2001 suppress
..
----------------------------------------------
ALU-12>config>log>filter#
Configuring Throttle Rate
This command configures the number of events and interval length to be applied to all event
types that have throttling enabled by the event-control command.
Use the following CLI syntax to configure the throttle rate.
CLI Syntax: config>log#
throttle-rate events [interval seconds]
The following displays an example of the configuration command syntax:
Example: config>log# throttle-rate 500 interval 10
config>log# event-control mpls 2001 generate throttle
The following displays the configuration:
*A:gal171>config>log# info
---------------------------------------------
throttle-rate 500 interval 10
event-control “mpls” 2001 generate throttle
----------------------------------------------
*A:gal171>config>log#