Log Management Tasks
Page 238 7705 SAR OS System Management Guide
Returning to the Default Event Control Configuration
The no form of the event-control command returns modified values back to the default
values.
Use the following CLI syntax to return to the default event control configuration:
CLI Syntax: config>log
no event-control application [event-name | event-
number]
The following displays an example of the command usage to return to the default values:
Example: config# log
config>log# no event-control "atm" 2014
config>log# no event-control "filter" 2001
config>log# no event-control "mpls" 2001
ALU-12>config>log# info detail
----------------------------------------------
#------------------------------------------
echo "Log Configuration"
#------------------------------------------
...
event-control "atm" 2004 generate minor
event-control "atm" 2005 generate warning
event-control "atm" 2006 generate warning
event-control "atm" 2007 generate critical
event-control "atm" 2008 generate warning
event-control "atm" 2009 generate warning
event-control "atm" 2010 generate warning
event-control "atm" 2011 generate warning
event-control "atm" 2012 generate warning
event-control "atm" 2013 generate warning
event-control "atm" 2014 generate warning
event-control "atm" 2015 generate warning
event-control "atm" 2016 generate warning
event-control "atm" 2017 generate warning
...
----------------------------------------------
ALU-12>config>log#