Installing PSUs
7750 SR-a4 and SR-a8 Installation Guide 93
Note:
The 7750 SR-a4 chassis requires a minimum of one PSU to operate, but two are
recommended for redundancy. The 7750 SR-a8 chassis requires a minimum of two
PSUs to operate, but four are recommended for redundancy.
For full redundancy, each PSU module should be attached to an independent power
source with a dedicated circuit breaker. A fully redundant system must be connected to
both DC PSU modules, or both AC PSU modules, or one DC and one AC PSU module.
In the event of a PSU module failure, the entire AC or DC PSU must be replaced. There
are no field-serviceable parts inside the PSU.
Empty PSU slots in the chassis must be covered by impedance panels. Panels must be
ordered separately. See
Impedance Panels on page 43 for more information.